Gas Flow Meters and Liquid Meters

Special use case: Gas Flow Meter and Liquid Meter tracking is only configured for organizations that require it. If you do not see these at your locations, this feature is not enabled for your organization.

What Are Gas Flow Meters and Liquid Meters?

EZ Ops tracks two types of metering equipment under the Site Data section:

Gas Flow Meters (Meter Runs) measure gas flow rate. They are characterised by their pipe size and orifice plate size.

Liquid Meters measure liquid volume. They are characterised by a K-factor (pulses per unit volume) and the type of fluid being metered (e.g., crude oil, produced water).

Both types share the same tracking system — service dates, inspection schedules, and replacement history — with type-specific fields where needed.


Viewing Gas Flow Meters and Liquid Meters

Meters are visible on the plant or field location page in the Site Data section. Each record shows itsentifying information, in-service status, and service dates.


Creating a Meter

  1. Navigate to the plant or field location
  2. Open the Site Data section
  3. Click Add Gas Flow Meter or Add Liquid Meter
  4. Fill in the details
  5. Save

Shared Fields (both types)

Field:Location Description
Notes: Free-text description of where the meter is physically located on site

Field:Manufacturer
Notes: Manufacturer name

Field:Serial Number
Notes: Serial number for this unit

Field:Model Number
Notes: Model name/number

Field:Last Service Date
Notes: Date of most recent service

Field:Next Service Date
Notes: Date service is next due

Gas Flow Meter — Additional Fields

Field:Meter Run Size
Notes: The pipe/run size

Field:Meter Run Orifice Size
Notes: The orifice plate size

Liquid Meter — Additional Fields

Field:K-Factor
Notes: Pulses per unit volume — used to calculate flow from pulse count

Field:Liquid Material
Notes: The type of fluid being metered (e.g., Crude Oil, Produced Water)


Replacing a Meter

Use Replace when a meter is physically swapped out for a new unit. Do not use the edit function to record a replacement — Replace creates a proper historical record of the change.

  1. Open the meter being replaced
  2. Click Replace
  3. Fill in the details for the new unit
  4. Save

What happens:

  • The old meter is set to inactive
  • All active inspection schedules from the old meter are cloned onto the new meter record — the inspection program continues without interruption
  • The old meter's inspection schedules are deactivated
  • Any linked operational actions are deactivated

Meters and Inspections

Both Gas Flow Meters and Liquid Meters can be assigned inspection schedules by an admin. When an inspection is due, it appears on the site page for operators to complete.

Replacing a meter carries all current inspection schedules forward to the new record automatically — you do not need to re-assign inspections after a meter replacement.


Overview Reports

Two reports are available for meters:

Active Site Data Report — Lists all active Gas Flow Meters and Liquid Meters across all wells and plants in the organization. Liquid meters show their material type (e.g., "Crude Oil", "Produced Water").

Sites Without Site Data Report — Lists all wells that are missing any of the three tracked site data types (PSV, Liquid Meter, Gas Flow Meter). Each well shows whether each type exists or is missing, making it easy toentify gaps in site data coverage.


Common Questions

"I replaced a meter but the inspection is now showing on both the old and new record"

  • After replacement, the old meter's inspections are deactivated. If both are showing, confirm the replacement was completed correctly. Contact your admin if the old record is still showing active inspections.

"The Site Data section isn't visible at my location"

  • This feature may not be enabled for your organization, or your admin may need to configure it. Contact your admin.

"The liquid material dropdown doesn't include the fluid type I need"

  • The available materials are pre-defined. Contact your admin to have a new material type added if needed.