PSVs and Vessels
Special use case: PSV and Vessel tracking is only configured for organizations that require it. If you do not see PSVs or Vessels at your locations, this feature is not enabled for your organization.
What Are PSVs and Vessels?
PSVs (Pressure Safety Valves) are safety devices that automatically open to relieve excess pressure when a system exceeds its design limit. EZ Ops tracks PSV records, their specifications, service dates, and which vessels they protect.
Vessels are pressure-containing equipment items — separators, treaters, tanks under pressure, etc. In EZ Ops, vessels serve as the reference point that PSVs are attached to.
PSVs and Vessels are tracked at the plant or field location level and can be assigned inspection schedules for periodic condition checks.
Viewing PSVs and Vessels
PSVs and Vessels are visible on the plant or field location page in the Site Data section. Each record shows its key identifying information, in-service status, and any attached relationships (PSVs show their attached vessels; Vessels show their attached PSVs).
Creating a PSV or Vessel on Site
New PSVs and Vessels can be created directly on the site page.
- Navigate to the plant or field location
- Open the Site Data section
- Click Add PSV or Add Vessel
- Fill in the record details
- Save
Auto-Move on Duplicate Serial/Manufacturer
EZ Ops checks whether the manufacturer and serial number you enter already exist on another record in the system. If a match is found, instead of creating a duplicate, EZ Ops relocates the existing record to the current site and detaches it from its previous location. All specifications on the existing record are updated with the values you entered.
This ensures a single record follows a physical unit as it is moved between sites, preserving its history.
PSV Fields Reference
| Field | Notes |
|---|---|
| Alias | Display name for this PSV |
| Serial Number | PSV serial number — used with manufacturer for duplicate detection |
| Model Number | Model name/number |
| Manufacturer | Manufacturer name — used with serial number for duplicate detection |
| Set Pressure | Rated set pressure with unit |
| Capacity | Flow capacity with unit |
| In Service | Whether this PSV is currently in service |
| Asset Type | Classification of the asset |
| Inlet / Outlet ANSI Flange | Flange specifications |
| Nozzle Type | Nozzle specification |
| Test Pressure | Pressure at which the PSV was tested |
| Commission Date | When the PSV was put into service |
| Last Service Date | Most recent service date |
| District | Geographic or administrative district |
| Abacus Number | External system reference number |
Vessel Fields Reference
| Field | Notes |
|---|---|
| Alias | Display name |
| Serial Number | Used with manufacturer for duplicate detection |
| Manufacturer | Used with serial number for duplicate detection |
| Provincial Reg Number (A-Number) | Alberta provincial registration number |
| CRN | Canadian Registration Number |
| Year Built | Year the vessel was manufactured |
| MAWP (PSI / KPa) | Maximum Allowable Working Pressure |
| Diameter | Vessel diameter with unit |
| Efficiency | Vessel efficiency rating |
| Shell Material / Thickness | Shell construction specifications |
| Head Type / Material / Thickness | Head construction specifications |
| Corrosion Allowance | Design corrosion allowance |
| Service | Service description (what fluid/service this vessel handles) |
| In Service | Whether the vessel is currently in service |
| Description | Free-text description |
| National Board Number | NBIC number |
| Commission / Decommission Date | Lifecycle dates |
| Design Life / Code Inspection Interval | Design specification |
| Coating | Coating description |
Attaching PSVs to Vessels
A PSV can be attached to one or more vessels it protects. This relationship is managed on the PSV record.
To attach a PSV to a vessel:
- Open the PSV record
- In the Attached Vessels section, select the vessel(s) this PSV protects
- Save
To detach a PSV from a vessel:
- Open the PSV record
- Remove the vessel from the Attached Vessels list
- Save
A PSV that is detached from all vessels is automatically set to inactive and its site location is cleared.
Replacing a PSV
Use Replace when a PSV is physically swapped out for a new unit. Do not use Update for replacements — Update is for correcting information on the same physical unit.
- Open the PSV being replaced
- Click Replace
- Enter the details for the new PSV
- If a service schedule is required, enter the next service date and frequency
- Save
What happens:
- The old PSV is taken out of service, removed from its site location, and marked as replaced
- Any machine schedules on the old PSV are deactivated
- If the new PSV has service schedule details, a new service schedule is created
- EZ Ops checks for an existing record matching the new PSV's serial+manufacturer. If found, that record is reused (auto-move logic applies)
Replacing a Vessel
Use Replace when a vessel is physically swapped out for a new unit.
- Open the vessel being replaced
- Click Replace
- Enter the details for the new vessel
- Save
What happens:
- All active inspection schedules from the old vessel are carried over to the new vessel record, preserving continuity of the inspection program
- The old vessel's schedules are set to inactive
- The old vessel is marked as replaced