Skip to content
English
  • There are no suggestions because the search field is empty.

Tanks

 What is the Tanks Module?

The Tanks module in EZ Ops is used to monitor tank inventory and volume for two main use cases: chemical tanks (injection chemicals that decrease over time) and production tanks (oil, water, NGL, and other produced fluids that increase over time). Operators log tank readings to track current volume, and EZ Ops calculates rates and trends based on those readings.

For chemical tanks with pumps, pump rate logs are also used to document where and how much chemical is being injected going forward. Production tanks typically do not have pumps.

Tank level data can also be ingested automatically via the EZ Ops API or through the built-in integration with R3mote.io tank level sensors, reducing the need for manual readings on instrumented tanks.

Key point: Tank readings calculate what has happened (volume consumed or produced), while pump rate logs set what is intended to happen next — for chemical tanks with pumps, both steps should be completed together every visit.

Why Tanks Matter

The Tanks module is essential because:

  • Inventory visibility - Know exactly how much fluid (chemical or production) is in each tank at any location at any time
  • Consumption and production tracking - Identify how fast chemicals are being used or how fast production tanks are filling, and flag unusual changes in rate
  • Injection management - Document pump rates per well and injection point to ensure the right amount of chemical is going to the right place
  • Planning - Tank reports help foremen plan chemical fills and production hauls based on actual rates across a field
  • Sensor integration - Instrumented tanks can feed readings automatically via R3mote.io or the EZ Ops API, reducing manual gauging
  • Inspections - Tanks can be assigned inspection schedules to ensure they are kept in proper condition
Tank Configuration

Tanks are configured by administrators and belong to either a plant or a field location. Each tank stores:

  • Orientation and dimensions - Physical setup of the tank
  • Manufacturer, model - Equipment documentation
  • Size units - Configured as bbl, m³, imp gal, or US gal depending on your organization's preference
  • Coefficient - The conversion factor (m³/cm) used to calculate volume from a height measurement on vertical tanks
  • Gauge charts - For horizontal tanks, a gauge chart (a lookup table of level-to-volume values) is stored in EZ Ops to allow accurate volume calculations, since the geometry of a horizontal tank makes a simple coefficient inaccurate
  • Instructions - Reading instructions can be added to the tank to guide operators on how to take an accurate reading
Understanding Tank Readings vs. Pump Rates

For chemical injection tanks, there are two separate but related steps that should be completed together every visit:

Tank Reading Pump Rate Log
What it tracks Current volume / level in the tank Intended future injection rate per pump
What it calculates Volume consumed since last reading; calculated rate based on historical data Sets the documented rate per injection point going forward
When to do it Every site visit Every site visit (when rates change or to confirm current rates)
Applies to All tanks Chemical injection tanks with pumps only

The calculated rate shown after a tank reading reflects what the pumps/flow activity has been historically. The manual pump rate is what you are setting as the intended rate going forward. Both together give foremen and operators a complete picture.

Production tanks (oil, water, NGL, etc.) track volume that increases over time as production accumulates. They typically do not have pumps and do not require pump rate logs — only tank readings are needed.

Measurement Units for Tank Readings

When logging a tank reading, the measurement type and unit can vary by tank configuration:

Level / height measurements:

  • cm
  • Inches
  • Meters (height)
  • Percentage (%)

Volume measurements:

  • m³
  • bbl
  • US gal

EZ Ops uses the tank's coefficient to convert level measurements (like cm or inches) into volume automatically.

How to Log a Tank Reading — Grid View (Recommended)

The Grid View is the fastest way to log readings across multiple tanks with fewer clicks. It is the recommended method for routine visits.

  1. Navigate to the location - Go to the plant or field location that has the tanks
  2. Open the Tanks section - Click on Tanks in the EZ-Nav
  3. Grid View opens by default (if enabled) - If your organization has enabled Grid View, it will open as the default view for tanks. Otherwise, you can manually switch to Grid View.
  4. Enter readings for each tank - In Grid View, all tanks are displayed in a condensed layout. Enter the level or volume reading for each tank directly in the grid.
  5. Enter pump rates - Update the pump rates for each pump attached to the tanks in the same grid interface.
  6. Entries auto-save - As you enter readings and pump rates in Grid View, your changes are automatically saved—there is no need to click a separate Save button.
How to Log a Tank Reading — Detailed View

The Detailed View provides more information and options per tank and is useful when you need to review historical data, graph trends, or update tank documentation. This is also where you can edit tank details, edit pump details, add suggested rates to pumps, and see the history of previous logs.

  1. Navigate to the tank - Go to the location and click on the specific tank from the list
  2. Review tank details - Check the reading instructions and any relevant tank documentation at the top of the page
  3. View historical readings - Scroll through the list of previous tank readings to see volume changes and calculated rates over time
  4. Edit tank details - Update tank-specific information such as reading instructions, manufacturer, model, or other documentation details
  5. Click "Add Tank Reading" - This opens the reading entry form
  6. Enter the level or volume - Input the current measurement in the appropriate unit for that tank
  7. Review the calculated rate - After saving, EZ Ops shows a calculated rate based on the change from the previous reading
  8. Log pump rates - Return to the tank and update the pump rates for each attached pump to reflect the intended injection rates going forward
  9. Edit pump details - Update pump-specific information such as well location, injection point, or pump on/off state
  10. Add suggested rates to pumps - Set seasonal suggested rates to help operators and foremen assess whether the current rate is appropriate for the time of year
Understanding Pumps

Pumps are attached to tanks and document chemical injection. Each pump records:

  • Well location - Which well the pump is injecting into
  • Injection point - Tubing, casing, or pipeline
  • Pump rate - The amount of chemical being injected

Pump on/off state:

  • A pump can be turned on or off
  • When a pump is off, only a rate of 0 can be entered — this prevents accidental active rate logging for a pump that is not running
  • Suggested seasonal rates can be set on pumps to help operators and foremen assess whether the current rate is appropriate for the time of year
Tank Inspections

Tanks can be assigned inspection schedules just like other items in EZ Ops. When a tank inspection is due:

  • It will appear in the Inspections section on the tank or location page
  • Complete the inspection as you would any other
  • Failed inspection questions will auto-generate tasks assigned to the person who completed the inspection
Automatic Tank Level Data Ingestion

For instrumented tanks, EZ Ops can receive tank level readings automatically without manual entry:

  • R3mote.io integration - EZ Ops has a built-in integration with R3mote.io tank level sensors. When configured, sensor readings flow directly into EZ Ops as tank readings, keeping data current between manual gauging visits
  • API endpoint - EZ Ops also provides an API endpoint for ingesting tank level data from other sensor platforms or third-party systems

Automatically ingested readings appear alongside manually entered readings in the tank history and graph view. Contact your EZ Ops administrator or the EZ Ops team to configure sensor integrations for your tanks.

Common Issues

"The volume doesn't look right after I entered a reading"

  • Verify the reading was entered in the correct unit for that tank (the tank configuration sets what unit is expected)
  • Check that the tank's coefficient is correctly configured — contact your administrator if the conversion seems off
  • Ensure you are reading the tank the way the instructions describe (e.g., from which reference point to measure)

"I can't enter a rate for a pump"

  • If the pump is turned off, only a rate of 0 is allowed — check the pump's on/off state
  • If the pump should be active, turn it on first before logging a rate

"I don't see a pump attached to my tank"

  • Pumps can be created from the Tanks section on the location page — operators can create pumps offline
  • If pumps should already exist and are missing, sync your device and check again

"I can't find the Grid View"

  • Grid View is available on the Tanks section of any location page — if you only see Detailed View, look for a view toggle at the top of the tanks list
Tips & Recommendations
  • Log the pump rate after every tank reading - The reading records what happened and the rate sets what should happen next; the pair is what makes the record useful.
  • Confirm the pump rate even when nothing has changed - Confirming creates a documented record of intent. Skipping it leaves an ambiguous gap that reads as a missed visit.
  • Investigate a calculated rate that disagrees with the pump rate - A large gap can point to a pump problem, a leak, or a rate that needs adjusting.
  • Use Grid View when several tanks are on the same visit - It cuts the clicks per tank considerably compared with opening each one.
  • Measure from the same reference point each time - Readings are only comparable over time if the conditions they were taken in are comparable too.